GB
Mains voltage
Permissible load at
60% duty cycle
80% duty cycle
100% duty cycle
Setting range (DC)
Open circuit voltage
Open circuit power
with cooling unit
Power factor at maximum current
Efficiency at maximum current
Control voltage
Dimensions lxwxh
Weight
with cooling unit
Operating temperature
Enclosure class
Application classification
Cooling unit
Cooling power
Coolant
Coolant quantity
Maximum water flow
Duty cycle
The duty cycle refers to the time as a percentage of a ten–minute period that you can weld at a cer-
tain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
ba36d2ea
ESABMig 500t
230/400–415/500V, 3∼ 50Hz
230/440–460/575V, 3∼ 60Hz
500A / 39V
435A / 36V
390A / 33,5V
50A/16.5V–500A/39V
53–60V
720W
920W
0,90
78%
42 V, 50/60Hz
31,5 x 25,2 x 32,9inch (800 x 640 x 835mm)
523lb (237kg)
553lb (251kg)
+14 to +104°F (–10 to +40°C)
IP 23
2500W at 104°F (40°C) temp. difference and flow
0,4gal/min (1,5l/min)
50% water / 50% glycol
1,5gal (5,5l)
0,5gal/min (2,0l/min)