Do not place the device in the vicinity of an open flame, electric ovens, heating
stoves or other heat sources, such as direct sunlight. High temperatures may
adversely affect cooling performance and power consumption.
The device should be set so that there is an adequate supply of air circulation. Keep
a 10 cm clearance on the sides and rear, and 30 cm from the ceiling or cabinets.
Never cover and do not block ventilation openings.
Do not place the device in places where there is high humidity. Too much moisture
can cause damage to the device. The optimum operating conditions at the set device
is achieved at ambient temperatures between 10 ° C and 30 ° C and relative humidity
between 30-55%.
In order to avoid damage to the legs or other equipment, in the case of moving,
lift the device (eg. by forklift).
Place the device so that the plug is easily accessible in order to quickly
disconnect the device from the power supply if need arises.
After placing the device in the intended place, level it by tightening or loosing the feet.
Remove the protection foil from the device before the first use.
CAUTION!
Never remove the rating plate and any warning signs from the device.
Connection
DANGER! Electric shock hazard!
The device can cause injuries due to improper installation!
Before installation and connecting the local power grid
specification should be compared with that of the device
(see rating plate). Connect the device only in case of
compliance!
If during transport the device was placed horizontally, the connection may
occur only after a period of 2 hours (built-in condensing unit).
After a power failure or if the plug is removed, the device should not be
connected to the power supply for at least 5 minutes.
The power supply circuit with the socket must be protected by the fuse of at least 16A.
Connect the device directly to a single grounded socket. Do not use any power bar or
multiple socket.