8.6 Checking the power tool after care and
maintenance
After carrying out care and maintenance work on the
power tool, check that all protective and safety devices
are fitted and that they function faultlessly.
en

9 Troubleshooting

Fault
The power tool doesn't run.
The on / off switch can't be
pressed, i.e. the switch is
locked.
Running speed suddenly drops
considerably.
The battery runs down more
quickly than usual.
The power tool doesn't restart
by itself after the saw blade has
stalled.
The battery doesn't engage with
an audible double click.
The tool or the battery become
very warm.
No / reduced suction power.

10 Disposal

CAUTION
Improper disposal of the equipment may have serious consequences: the burning of plastic components generates
toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to very high
temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal may permit
unauthorized and improper use of the equipment. This may result in serious personal injury, injury to third parties and
pollution of the environment.
CAUTION
Dispose of defective batteries without delay. Keep them out of reach of children. Do not attempt to open or dismantle
batteries and do not dispose of them by incineration.
28
Possible cause
The battery is discharged or fitted
incorrectly.
Electrical fault.
The battery is discharged/hot.
Not a fault (safety function).
The battery is discharged or the work-
ing pressure applied to the power tool
is too high.
Battery condition is not optimal.
The deep discharge prevention sys-
tem has switched off after the blade
has stalled a second time.
The retaining lugs on the battery are
dirty.
Electrical fault.
The power tool has been overloaded
(application limits exceeded).
Chip ejector channel blocked.
Remedy
The battery must be heard to engage
with a double click or, respectively,
needs to be charged.
Remove the battery from the power
tool and contact Hilti Service.
Deep discharge prevention / the elec-
tronics switch off. Insert the battery in
the charger or allow it to cool down.
Press the switch-on interlock.
Change the battery and recharge the
discharged battery. Reduce the work-
ing pressure applied to the power
tool.
Only NiCd batteries should be given
a conditioning charge. (Please refer
to the operating instructions for the
charger.)
Press the switch-on interlock and the
on/off switch again.
Clean the retaining lugs and check
that the battery engages securely.
Contact Hilti Service if the problem
persists.
Switch the power tool off immedi-
ately, remove the battery and contact
Hilti Service.
Use the right power tool for the job
(don't use a low-powered tool for
heavy work).
Clean out the chip ejector channel.

Publicité