HARD WIRING INSTALLATION

TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE

HARD WIRING CONNECTION

If it is necessary to hard wire this appliance, a qualifi ed electrician must remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
Fig. 1
A.
Remove the cover plate from the right side
bottom of the appliance by removing the three
screws, as shown above.
C.
Take the new cover plate, supplied in the hardware bag. Punch out the 7/8" (22.2mm) hole and install
a box connector through, into the junction box. Snap the box connector clamp onto the supply wires.
D.
Using the wire connectors, connect the ground green wires (G), the common white wires (N)
together, then the hot black wires (L) and then the refer to Figure 3.
E.
Reinstall the cover plate using the three screws, as shown in Figure 1.
Fig. 3
G
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.

COVER PLATE

N
L
WARNING
!
B.
Remove the wire connectors from the power
cord. The power cord may be discarded.