Appendix
•
A leaking battery cap may lead to the destruction of XP10 by water seeping in or cause XP10
to switch off without prior notice.
•
Always open the battery compartment in a dry and clean environment.
•
Only open the battery compartment to replace the battery.
F
Protect the environment and dispose the battery properly.
If you notice traces of seeping water, damages, or other defects on the o-ring, do not use XP10
for further dives. Take it to an authorized SUBGEAR dealer for check and repair.
6. Always insert a new o-ring when you replace the battery and dispose the old o-ring. Make sure
that the new o-ring is in perfect condition, and that o-ring, o-ring groove and the sealing surfaces
are free of dust and dirt.
If necessary, clean the parts with a soft cloth. Fit the o-ring in the o-ring groove of the battery cap.
7. Use only an original SUBGEAR o-ring. This o-ring is Teflon coated and does not require
additional lubrication.
8. Do not lubricate the o-ring as the lubricant will chemically attack the battery cap.
9. Check the proper polarity of the battery. XP10 can be damaged if you do not
After battery replacement XP10 will perform an automatic test (8s) and gives a short beep when the
test is done.
38
! WARNING
1. Dry XP10 with a soft towel.
2. Turn the battery cap with a coin or an universal tool.
3. Remove the battery cap.
4. Remove the o-ring carefully. Do not damage the sealing surfaces.
5. Remove the battery. Do not touch the contacts.
! WARNING
! WARNING
! WARNING
insert the battery correctly.
Insert the new battery, with "+" pointing outwards, into the battery
compartment.
universal tool