Operation / SOS
2.11 Switching off the display
From the time of day display you can switch off XP10 by pushing
On the surface XP10 switches off automatically after 3 minutes without operation.
2.12 Alarm clock
The alarm clock goes off only at the surface.
If the alarm clock is "on", the time of day display shows
When alarm is triggered:
the user presses a button.
Setting the alarm clock: ->34 ("set 2")
3 SOS mode
Time remaining until
SOS mode switches
off automatically
NO
DESAT
Diving within 48 hours after the end of an SOS mode will result in shorter no stop times or longer
decompression stops.
•
Serious injury or death may result if a diver does not seek immediate treatment should any
signs or symptoms of decompression sickness occur after a dive.
•
Do not dive to treat symptoms of decompression sickness!
16
flashes and special attention beeps are played for 30 seconds or until
Activation: automatic
If the diver remains above a depth of 0.8m (3ft) for more than three minutes
without observing a prescribed decompression stop, the computer will
automatically switch into SOS mode after the dive.
Push
to see the "SOS" sign and the remaining length of the SOS mode.
The dive will be entered in the logbook with "SOS".
The SOS mode will be unlocked after 24 hours.
While in SOS mode, the computer cannot be used for diving.
! WARNING
.
.