Installer Settings: Tables To Be Filled In By Installer; Quick Wizard; Space Heating/Cooling Control; Domestic Hot Water Control [A.4] - Rotex RHBH04CA3V Manuel D'utilisation

Masquer les pouces Voir aussi pour RHBH04CA3V:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26

4 Energy saving tips

3.7
Installer settings: Tables to be filled in by
installer

3.7.1 Quick wizard

Setting
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
BUH type
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
Space heating/cooling settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW operation
DHW tank heater
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter 1
External kWh meter 2
Capacities (energy metering) [A.2.3]
Booster heater
BUH: step 1
BUH: step 2
Bottom plate heater
Operation manual
7
Default
Fill in...
1 (1P,(1/2))
0 (LWT
control)
0 (In room)
1 (1 LWT
zone)
1 (1 LWT
zone)
1 (Sample)
Depends on
model
Depends on
model
0 (No)
2 (Thermo
ON/OFF)
2 (Thermo
ON/OFF)
0 (No)
0 (No)
0 (No)
0 (Normally
open)
0 (No)
0 (No)
0 (No)
0 (No)
0 kW
Depends on
model
Depends on
model
0 W

3.7.2 Space heating/cooling control

Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Set weather-dependent heating
Set weather-dependent cooling
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Set weather-dependent heating
Set weather-dependent cooling
Leaving water temperature: Delta T emitter [A.3.1.3]
Heating
Cooling
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type

3.7.3 Domestic hot water control [A.4]

Setting
Setpoint mode
Setpoint readout type
Maximum setpoint
INFORMATION
It is recommended NOT to use the selection of ([6-0D]=0,
[A.4.1] Domestic hot water Setpoint mode=Reheat only) in
case of a domestic hot water tank without internal booster
heater.
The risk of space heating (cooling) capacity shortage/comfort
problems is significant (in case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruption will happen).

3.7.4 Contact/helpdesk number [6.3.2]

Setting
Contact/helpdesk number
4
Energy saving tips
Tips about room temperature
Make sure the desired room temperature is never too high (in
heating mode) or too low (in cooling mode), but always
according to your actual needs. Each saved degree can save up
to 6% of heating/cooling costs.
Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low.
It will take more time and energy to heat up the room again.
RHVH/X04+08S18CA+RHVH/X08S26CA+RHVH/X16S18+26CA +
Default
Fill in...
0 (Absolute)
25/40/15/ 10
18/22/35/20
0 (Absolute)
25/40/15/ 10
18/22/35/20
5°C
5°C
0 (No)
1 (Slow)
Default
Fill in...
2 (Scheduled
only)
0
(Temperature)
Depends on
model
Default
Fill in...
RHBH/X04+08+16CA
Rotex HPSU low temperature Bi-Bloc
4P330421-1A – 2012.11