44

1. Introduction

The Mini Bio Luxury boiler with maximum power of 12 [kW] and 21[kW] and
with automatic pellet feeding sets new trends in utilising biological fuel. The
Mini Bio Luxury boiler can, without exaggeration, be called a 'heating system' ,
as this one device constitutes the best quality, fully equipped and automated
product. The reliable horizontal boiler design with flue tubes allows for the
optimal use of heating surface and does not expose the exchanger section to
excessive thermal loads while maintaining compact dimensions. Our company
offers reliable, durable and cost-effective solutions. The device has the capabili-
ty to automatically burn biomass in the form of pellets. The simple and intuitive
operation of boiler/boiler room control systems is also important to the user.
The large graphic touch screen display combined with the ergonomic and clear
interface of the boiler control system make our solutions easy to use.

2. General

The operation manual is an integral part of the boiler and must be provided to
the user of this device. Install the product in accordance with this User Manual,
relevant standards and practices. Boiler operation conforming to the User
Manual guarantees safe and failure free functioning and is a precondition for
the manufacturer's warranty coverage. The specifications may change without
notice.
KOSTRZEWA IS NOT LIABLE FOR ANY DAMAGE DUE TO
INCORRECT INSTALLATION OF THE PRODUCT OR FAILURE
TO OBSERVE THE CONDITIONS SPECIFIED IN THIS USER MANUAL.
Leader in pellet boilers

3. Scope of delivery

The Mini Bio Luxury boiler is provided on a wooden 1350x900 mm
pallet including:
boiler fitted with a control system including a ceramic chamber
and swirl vanes
Platinum Bio VG 12kW/24kW burner (burner power depending
on boiler power)
feeder chute
flexible hose
cleaning tool kit
user manual

4. Design guidelines

THE INSTALLATION AND ALL CONNECTIONS MUST COMPLY
WITH RELEVANT STANDARDS AND REGULATIONS!
a. Boiler location requirements
The distance of boiler walls and accessories from the room walls must guarantee
easy and failure free operation of the hot water boiler (boiler control system
operation, efficient manual fuel feeding to the storage hopper, repairs,
inspections etc.). Ensure sufficient space when planning and installing the
boiler and its accessories in the distance required to open all boiler doors, clean
the combustion chamber and the exchanger baffles.
The following diagram (see 'Boiler location in the boiler room - dimension
diagram') and table (see 'Boiler dimension data') show the recommended
installation space for the boiler and its accessories.
Table 1. Boiler room dimension data
Boiler room dimensions
Marking
A1
B1
C1
H1
g
Mini Bio Luxury 12; 21kW User Manual – EN 10.17
Unit
≥500mm
≥ 700mm
≥500mm
≥2000mm
≥ 50mm