5.3.1 FINISHING SUPPORT ADJUSTMENT
Depending on the fi nishing material we have allowed from 0" (0mm) to 3/4" (19mm) of adjustment after the
1/2" (13mm) non-combustible board has been installed. Loosen the 8 screws on each fi nishing support. Adjust
EN
the fi nishing support to the desired position.
NOTE: Peninsula models have one end support that can also be adjusted by loosening the two screws.
1/2"
(13mm)
MIN
W415-1283 / 05.02.14
B
NOTE: Framing dimension "A" and "B" will be affected as the fi nishing
supports are adjusted outwards, refer to "FRAMING" section".
FINISHING
FINISH SUPPORT
MATERIAL
POSITION
1/4" (6mm)
1/2" (13mm)
1/2" (13mm)
1/4" (6mm)
3/4" (19mm)
Flush 0" (0mm)
SIDE VIEW
A
1/2"
Combustible
Board
Finish
support
1/2"
Combustible
Board
Finish
support
1/2"
Combustible
Board
Finish
support
1 1/2"
(38mm)
MAX
1/4"
Finishing
Material
1/2"
Finishing
Material
3/4"
Finishing
Material