9.3
FLAME CHARACTERISTICS
It's important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.
LOG BURNER
GLASS BURNER
FLAME SENSOR
PILOT
ELECTRODE
BURNER
3/8" - 1/2"
(9.5mm - 12.7mm)
3/8" - 1/2"
(9.5mm - 12.7mm)
ELECTRODE
FLAME
SENSOR
FLAME MUST ENVELOP
FLAME MUST ENVELOP
UPPER 3/8" (9.5mm) TO 1/2"
UPPER 3/8" (9.5mm) TO 1/2"
(12.7mm) OF FLAME SENSOR
(12.7mm) OF FLAME SENSOR
54.1B
47
EN
PILOT
BURNER
W415-1283 / 05.02.14