Wiring - Empire Heating Systems DVC55SPPXLP-1 Instructions D'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wiring

The appliance, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70 or
Canadian Electrical Code, CSA C22.1, if an external electrical
source is utilized. This appliance is equipped with a three-
prong [grounding] plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug. For an ungrounded
receptacle, an adapter, which has two prongs and a wire for
grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting
screw. With this wire completing the ground, the appliance
cord plug can be plugged into the adapter and be electrically
grounded. a
" hole is provided in the junction box for use
7/8
with a conduit connector if local codes require this type of
protection.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after
servicing.
To Conserve Gas: Turn off pilot when heater is not in use.
Installing the ON/OFF Device
To install an ON/OFF device (such as a wall switch, remote,
toggle switch, or thermostat), remove the wire nut from the
two wires from the valve. Run additional wire from the valve
wires to the ON/OFF device. Install the ON/OFF device in the
same room as the furnace following the installation instruc-
tions supplied with it. In the absence of instructions, install the
ON/OFF device 4 to 5 feet above the floor on an interior wall
not affected by another heating source (i.e. stove or water
heater) or the temperature of an adjoining room.
Page 14
WIRING
SCHEMATIC WIRING DIAGRAM
——————————————————————————————
SCHÉMA
INSTALLATION LECTRIQUE
É
WHITE (BLANC)
BLACK (NOIR)
LIMIT CONTROL
AUTO FAN
———
——————————— —
— ————
———
———————
—— ————
CONTROL DE
VENTILATE
TOLERANCE
AUTO
SPT-3 CORDSET
WIRE NUT
———
———————————
CORDON SPT-3
———————---------------- —
— ————
FILS TORSADÉS
TRANSFORMER
———
——————————————
—— ————
TRANSFORMATEUR
ON/OFF DEVICE
———
——————————— —
— ————
ON/OFF
PÉRIPHÉRIQUES
GAS VALVE
———
—————————
—— ————
VALVE DE GAZ
JUNCTION BOX
——
——————————
—— ——— ————
BOÎTE DE JONCTION
LOW VOLTAGE (BAS VOLTAGE)
120 VOLTS
LADDER WIRING DIAGRAM
——————————————————————————
DIAGRAMME À L´ÉCHELLE
D´INSTALLATION ÉLECTRIQUE
120 VOLTS
YELLOW
BLACK
———
————————
———
————————
JAUNE
NOIR
AUTO FAN
MOTOR
———
———————
—— ————
VENTILATEUR
————— ————
MOTEUR
AUTO
RED
RED
ROUGE
ROUGE
TRANSFORMER
———
——————————————
—— ————
TRANSFORMATEUR
PÉRIPHÉRIQUES
VALVE DE GAZ
24 VOLTS
LIMIT CONTROL
WIRE NUT
———
——————————— —
CONTROL DE
———————---------------- —
— ————
FILS TORSADÉS
TOLERANCE
ON/OFF DEVICE
———
——————————— —
— ————
ON/OFF
GAS VALVE
———
—————————
—— ————
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
WITH THIS UNIT MUST BE REPLACED, IT MUST
BE REPLACED WITH 150°C THERMOPLASTIC
4/64 THICK OR ITS EQUIVALENT.
120V. 60Hz. LESS THAN 3 AMPS
——————
———————————————————————————
————————————————————
S´IL Y A UN FIL ORIGINAL FOURNI AVEC
L´APPAREIL QUI DIOT ÊTRE REMPLACÉ. IL DOIT
ÊTRE REMPLACÉ AVEC UN FIL
THERMOPLASTIQUE 150°C.
120V. 60Hz. MOINS DE 3 AMPS.
Figure 13
MOTOR
————— ————
MOTEUR
—— ————
WHITE
———
————————
BLANC
— ————
32188-0-0616

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dvc55sppxnat-1

Table des Matières