AdvErSE rEActIonS
None known.
2. stanDaRD CoMPonents
Before set-up, check that all parts are present in the box (see Fig. 1):
• Central unit with cords and foot pedal
• Handpiece
• Tip wrench
• User manual Notes
F
Notes
• None of the components are delivered disinfected or sterilized!
• Prior to installation, check the device for damage. Report any damage sustained
during shipment to your local supplier within 24 hours of receipt of the device.
3. DesCRIPtIon
Front panel (see Fig. 2)
The power adjustment knob is used for switching the unit ON/OFF (ON is indicated
by the green LED) and setting the ultrasonic power levels from 1 to 20 according to the
recommended power range for each tip.
F
Notes
• See detailed directions for use of tips in section 4.3. "Operating the Unit".
• Specific DFUs can be found in the Individual Tip Guide.
• This device has been designed especially for endodontic root canal treatment, but can
also be used for scaling, periodontic and other general dental applications. For details
see section 4.3.2. "Other Applications."
rear panel (see Fig. 3)
There are four connections and one knob on the rear panel.
– The power cord to connect the device to the electrical supply (11).
– The foot pedal cord to operate the unit (10).
– The water supply tube including a filter (9).
– The handpiece cord to connect the device to the handpiece (8).
On the right hand side there is the water flow adjustment knob (7).
4. steP-by -steP InstRuCtIons
4 .1 . InStALLAtIon
F
Notes
• The ProUltra Piezo Ultrasonic should be connected to the electrical supply in accordance
with current standards.
• The water supply system should satisfy the quality criteria required for dental treatment.
In addition, it should be equipped with a water supply back flow prevention system.
1. Carefully remove the unit and the accessories from their packing and place them
properly on a flat surface in the desired location. Check that the power adjustment
knob is set to position OFF.
2. Contact your local Service Technician in order to connect the water tube to the water
supply.
3. Connect the power plug to an electrical socket.
4. Place the foot pedal properly to make operation easy.
5. Connect the handpiece carefully by plugging it into the connector cord, aligning the
electrical contacts (see Fig. 4 below).
WarNiNG
Neither rotate the handpiece nor twist
the handpiece connector on its cord.
6. Place the handpiece with the head
ahead on the handpiece holder
(holder pivotable by 60°).
4 .2 . BEForE oPErAtIng tHE unIt
1. Sterilize the handpiece after disconnecting (see section 5 "Sterilization").
2. Make sure there is no trace of moisture in the handpiece connection, if this is the case
then wipe it and dry it with the airblower. Then reconnect the handpiece carefully to the
handpiece connection without twisting and rotating.
3. Sterilize the tips prior to first use (see section 5.1.
"Sterilization"). Select the appropriate tip, and
connect it by screwing it on with the supplied
wrench. Tighten it moderately (see Fig. 5 below).
4. Check that all connections are properly made.
5. Prior to use, run a sufficient amount of water
for several minutes to clear the line by pressing
down the foot pedal with the power adjustment
knob at the lowest level (1).
11
Fig. 4 Handpiece Connection
Fig. 5 Tip Tightening with Wrench