Oase Water Jet Lightning Mode D'emploi Et Consignes De Sécurité page 9

Masquer les pouces Voir aussi pour Water Jet Lightning:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Correct electrical installation
− Oase units must be grounded and fused according to the directions via a fault current protection
switch (fault current < 30 mA).
− Contact your local electric company regarding the electrical connection values or prerequisites for
electrical installations.
− Should the connection cable be too short, we recommend to call in an approved professional electrici-
an to install a connection point within reach of the connection cable or an approved cable extension .
− Avoid excessive bending or chafing of cables.
− Every modification to the unit is commensurate with non-observance of the CSA approval or its directi-
ves. In such a case every guarantee or warranty becomes null and void.
WARNING
Risk of electrocution! Ensure that the cable connection points and their surroundings are dry.
The safety transformer and the plug connector of the power cables supplied are not water-tight, but only
rain and splash-proof. Do not route or fit in the water. Protect the plug connection from moisture. The
safety transformer must have a minimum distance to the pond edge of 2 m (6,6 ft). Route the connection
cable so that damage is excluded. Only use cables approved for outside use.
Only use the unit with the attendant safety transformer contained in our scope of delivery. Never open the
housing or its attendant components, unless this is explicitly mentioned in the operating instructions.
Always disconnect the power supply of all units located in water and of this unit prior to performing work
on the unit! For your own safety, consult a qualified electrician if you have questions or encounter prob-
lems!
Pos 21 /Alle Produkte/Hinweistext Permanentmagnet @ 2\mod_1137061932996_6.doc @ 12726
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the
function of pacemakers.
What you should do
− Isolate all units in the pond from the mains at all poles prior to starting work on the unit.
− Isolate all units in the pond from the mains at all poles prior to going in the water.
− Commission an approved professional electrician to carry out and service all electrical installations.
− At the first sign of a problem, disconnect the unit from the mains at all poles.
What not to do
− Do not use the unit if persons are in the water.
− Do not shorten the connection cable.
− Do not remove the earth conductor or the earth contact.
− Do not carry or pull the unit by the connection cable.
− Do not attempt to open the housing.
− Never remove the legends from the unit or the connection cable.
− Avoid pinching, bending or damaging the connection cable. A small cut, even only in the outer jacket,
could be sufficient to allow water to soak into the cable. When you detect damage, take the unit out of
operation immediately and remove it from the water. Ask your OASE dealer how to proceed further.
Never forget: every damage to the connection cable implies a high risk of electrocution. Should the
unit be operated anyway, every guarantee or warranty will immediately expire.
Pos: 25 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
-
English
-
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

50355

Table des Matières