Cafe CFE Manuel D'utilisation Et D'installation page 43

Réfrigérateurs à congélateur en bas
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting Tips... Before you
Problem
Photos not found
Freezer cooling, fresh food not cooling
Ice dispenser opens after closing freezer
drawer
Hot water does not work
Hot water continues to dispense for a
short time after releasing the knob
Difficult to open the Icebox door
Fresh food door not closing fully
Low brewing flow rate
Low brewing flow rate / water drips from
inner door
Brewer stuck in the door bracket
Brewer is not detected by the screen
menu or hot water leaking from top of
the brewer
Coffee dispensed with splash or bubble
bursting
Beverage quality not as expected
Liquid drips from the brewer after brewer
cycle is completed and the brewer is
removed from the bracket
Delay when using Keurig K-cup Pod
dispenser
After brewing, my powdered beverage is
not fully cleared from the used pod
Brewer lid is difficult to close
*Some models do not come equipped with the filter bypass plug. To obtain a free bypass plug, visit us on-line at
cafeappliances.com/service. In Canads, visit cafeappliances.ca/service.
42
Possible Causes
Photos not in JPEG format
Normal, when refrigerator first plugged in
or after extended power outage
Normal
Operation disabled
Low water pressure
Water supply line turned off or not
connected
Water filter clogged or filter/bypass plug not
installed
Water filter is partially clogged or low water
pressure (<40 psi)
Icebox door gasket might stick to main
door if it remains closed for a long duration
Fresh food door gasket may have
unseated and interfering with articulating
mullion operation
There may have been a dent at the bottom
of K-Cup causing the pin to pierce the
filter allowing coffee grounds clogging the
bottom pin
Top needle of the brewer clogged
Dispenser is in hot water dispense mode
instead of brew mode while the brew
module is installed
Incorrect assembly of brewer in the bracket Make sure the Keurig Logo is in the front.
Blocked vent hole in the brewer
You may be using non-standard or out
dated K-Cups
It is possible for liquids to be retained by
the brewer and drip when it is removed
To ensure a quality beverage is delivered,
a short delay is required to ensure the
refrigerator is operating correctly
Depending on size selected, the powder
may not dissolve fully. Some powdered
beverages develop into 'clumps' when left
sitting for some time
K-cup is not fully seated
schedule service
What to Do
Make sure the photos are in the root
Photos must be in JPEG format
Wait 24 hours for temperature in both
compartments to reach selected
temperatures.
The ice dispenser door may open after
closing freezer door to allow access
selected
Make sure water line is not kinked
See Installing the Water Line
Replace filter cartridge or remove filter
and install bypass plug*
Replace filter cartridge or remove filter
and install bypass plug* or increase water
pressure
Disengage the door latch, wait for 3
minutes then open the Icebox door
Reseat the gasket all the way in the
groove
Avoid using damaged/dented K-cups, and
clean the lower needle before next brew
clip and rinse brewer. Rinse brewer after
every use.
Cancel hot water dispense mode so
hot water tube will retract from the brew
module
Push brewer all the way in the brackets
Make sure the vent hole at the bottom of
the brewer is clear from food or any other
contamination
Recommend using official Keurig K-cups
that are not past expiration and have not
been damaged
drips when brewer is removed
Ensuring consistent, quality operation
requires the refrigerator to delay dispense
for a short period of time
Shake the powdered pods before brewing
to break up these clumps and allow better
clearing. For powdered beverage with no
filter, use the Cocoa cycle selection
Press K-cup all the way down into the
brewer prior to closing the lid. Lower
needle must puncture K-cup bfore closing
the brewer lid
49-1000586 Rev. 1

Publicité

Table des Matières
loading