• Empty batteries are not to be disposed of in the
household refuse, but they are to be handed in as
chemical waste.
Technical information
• Power supply: (2xAAA) batteries
• Frequence: 433.92Mhz
• Numbre of codes: 10
• Worktemperature: 0-50°C
• Dimensions: 110 x 50 x 19mm
4 Maintenance
4.1 Grease filter
Maintenance of the grease filter
The hood contains one metal grease filter.
Grease filter indication
Indication: 4 flashing indicator lamps
After 20 cooking hours, the 4 indicator lamps will start
to blink during 5 minutes, this indicates that the grease
filter has to be cleaned.
Access to the filter
Take hold of the right and left side of the plate (A) and
pull down simultaneously. Remove the filter (B) by
taking hold of its hook and pulling down.
Cleaning the filter
• in the dishwasher
• manually: in a hot solution of water and a liquid deter-
gent. Rince and allow to dry completely
The previous instructions need to be followed. If
not an increased fire hazard may occur.
Reset grease filter indication
When replacing the cleaned filter, you have to reset the
hood by pushing the [-] button during 5 seconds. If you
don't reset, the indicator lamps will continu blinking.
We advise you to clean your filter twice a month for an
optimal operation.
4.2 Recirculation (option)
Programme recirculation
When choosing for recirculation, always set the
recirculation program on the hood. Execute this
programming as follows:
• Do the programming with the motor switched off.
• Simultaneously press the [+] and the [-] keys for 5
seconds until the red LED flashes 5 times.
The following functions have now been enabled:
• The run-out time has been set to 30 minutes (instead
of the default 10 minutes). Make use of the 30 min-
utes run-out time.
• The cleaning indicator for the Monoblock recircula-
tion filter has been set to 200 operating hours.
Deactivate the recirculation:
• The motor must be switched off.
• Simultaneously press the [+] and the [-] keys on the
hood for 5 seconds until the third green LED flashes
3 times.
• The run-out time has been set to 10 minutes (instead
of 30 minutes). The cleaning indicator for recircula-
tion is off.
Cleaning indication
Indication: red indicator lamp lights up
The red indicator lamp will light up after 200 working
hours (time to regenerate the Monoblock recirculation
filter). The recirculation filter is to be found behind the
grease filter.
Refer to the manual of your recirculation kit for removing
and putting back the monoblock filter.
Regenerate the Monoblock recirculation filter
• The Monoblock can be regenerated up to 12 times.
This is done in the oven.
• Place the filter in the oven for 1 hour at 120°C. Pro-
vide sufficient fresh air in the room where the oven
has been placed, as smells can be released. Smells
can be released when baking certain kinds of fish.In
this case it is best to immediately regenerate the filter
in the oven.
Reset the Monoblock recirculation filter
The cooker hood (motor) must be running
Simultaneously press [+] and [–] for 5 sec. until the
red indicator lamp flashes 3 times for confirmation. If
the programming is not carried out, the programming
is automatically set after the chimney hood has been
switched on 10 times.
After a reset, the cleaning indication will be set to 200
hours.
Place the Monoblock recirculation filter
Refer to the manual of your recirculation kit for removing
and putting back the monoblock filter.
EN 19