Draft Bypass Adjustment - Kozy Heat Fireplaces POWER VENT Manuel

Pour utiliser avec le foyer au gaz à évacuation directe clw-72 et clw-40
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3 Draft Bypass Adjustment

NOTE: All Kozy Power Vent systems will be shipped with the draft
bypass in setting 5. Adjustment of the draft bypass setting would only
occur during troubleshooting or flame appearance adjustments.
The draft bypass system is factory set to setting 5; for certain vent
runs the draft bypass system will need to be adjusted. To adjust the
draft bypass, loosen the locking screw. Adjust clock wise or counter
clockwise depending on your specific installation. See Figures 2.4,
2.5, and 2.6.
Table 2.2, Callaway 72 - Draft Bypass Setting Chart
Natural Gas
Draft Setting
#1
Not Allowed
#2
Not Allowed
#3
Allowed
#4
Allowed
#5
Allowed
* This draft setting is allowed on all vent configurations except a vent
configuration with a vertical drop
Table 2.3, Callaway 40 - Draft Bypass Setting Chart
Natural Gas
Draft Setting
#1
Allowed
#2
Allowed
#3
Allowed
#4
Allowed
#5
Allowed
Kozy Power Vent #KPV
Propane
Allowed*
Allowed*
Allowed
Allowed
Figure 2.6, Loosen Locking Screw
Allowed
Propane
Allowed
Allowed
Allowed
Allowed
Allowed
Figure 2.7, Adjust the Draft Bypass
Figure 2.8, Shown in Position 3