Issue
Pilot and burner
extinguish while in
operation
Soot appears on glass
Flame burns blue and lifts
off burner
No reaction to command
22
Cause
No propane in tank
Incorrect glass assembly
installation
Incorrect vent cap installation
Vent cap blockage
Exhaust vent pipe leaking
exhaust gases back into firebox
Excessive draft
Improper media placement
Improper venturi setting
Incorrect vent cap installation
Vent cap blockage
Improper venturi setting
Incorrect vent cap installation
Blockage or leakage of the vent
system
Excessive draft
No communication between
remote control and IFC module
A maximum number of failed
ignitions or flame restorations
has been reached
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Check propane tank. Refill if necessary.
Adjust if necessary. See appliance installation manual.
Adjust if necessary.
Remove debris if necessary.
Check for leaks and repair if necessary.
Adjust the draft bypass system. Refer to Section 2.3 Draft Bypass
Adjustment on page 7.
See appliance installation manual.
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix.
Adjust if necessary.
Remove debris if necessary.
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix. See appliance installation manual.
Adjust if necessary.
Check the vent pipes for leaks, and the vent cap for debris. Repair the vent
pipes or remove debris from vent cap, if necessary.
Adjust the draft bypass system. Refer to Section 2.3 Draft Bypass
Adjustment on page 7.
Reprogram remote control to IFC module. See appliance installation
manual.
Reset IFC module. See appliance installation manual.
Solution