4.1.2 Wiring the KPV to the Appliance
NOTE: Use Figure 4.8 as wiring schematic references when following
the individual instructions below.
1.
Find the hole in either side of the fireplace for access to Power
Vent wiring. See the top picture of Figure 4.4 for your appliance.
The power vent wire harness hole is located on a removable
plate. Remove screws that attach this plate to the outer shell
for easier access. Reattach the plate when finished. Run the
loose wiring through the larger section of the opening until you
reach the start of the flexible conduit. Unscrew the nut from the
conduit end and slide the conduit end into the smaller section
of this opening. Screw the locking nut back on the threads of the
conduit securing it to the fireplace. See the bottom picture of
Figure 4.4.
2.
Locate the Power Vent IFC wire harness in the components
packet. Plug the connector into X12 and X13 plug receptor. See
Figure 4.5.
3.
The power vent wire harness has the black hot wire split with
two female quick connections on either end. Plugs these into the
black leads that have quick connections coming off the control
module in the X12 combustion blower location. See Figure 4.6.
4.
Locate the blue looped wire on the control module wire harness
that connects to the IPI/CPI location on the control module. Cut
this looped wires so you have two individual blue wires.
5.
Locate the yellow looped "APS" wire on the control module wire
harness. Cut this looped wire for two individual yellow wires.
Strip back approximately 1/2" of the end of each wire. Using the
(2) provided blue wire nuts, twist one of the yellow APS wires
into the brown wire coming from the vacuum switch in the
power vent assembly. Use the second blue wire nut to twist the
second yellow APS wire to the red wire coming from the vacuum
switch as shown in Figure 4.7.
6.
Run the other end of the power vent wiring to the power vent
termination assembly. For attaching the wire harness to the fan
and vacuum switch, refer to Section 3.5 on page 11.
7.
Connect the three prong plug into the electrical box in the
fireplace.
CLW-72 POWER VENT WIRE HARNESS HOLE LOCATION
Figure 4.4, Power Vent Wire Harness Hole Location
Kozy Power Vent #KPV
CLW-40 POWER VENT WIRE HARNESS HOLE LOCATION (RIGHT SIDE)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Figure 4.5, Power Vent IFC Wire Harness and X12 & X13 Location
Figure 4.6, Quick Connections to Black Leads
Figure 4.7, APS Wire Nuts
17