Hansgrohe Metropol 15720 Série Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible - Temperature regulator dirty or
Safety stop button not operating
Diverter stiff
Diverter leaking
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or
leaking
- Thermostat has not been adjusted
- Hot water temperature too low
calcified
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180 rotation
- Spring defective
- Button calcified
- Cartridge defective
- Dirt or sedimentation on valve seat. - Clean valve seat or exchange
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filters
- Clean filter seal between shower
and hose
- Clean backflow preventers,
exchange if necessary
- Adjust thermostat
- Increase hot water temperature to
42 C to 65 C
- Clean temperature regulator,
exchange if necessary
- Install function block turned through
180
- Clean spring and/or button,
exchange if necessary
- Clean spring and/or button,
exchange if necessary
diverter
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Metris 15720 sérieMetropol e 16720 sérieMetris e 15720 sérieTalis e 15720 sériePuravida 15771 sérieMetropol s 15721 série ... Afficher tout

Table des Matières