Remedy of faults
Malfunction
Pump does not switch on
Insufficient fountain height
The unit floats up

Maintenance and cleaning

• Cleaning the unit (E-H)
• For opening, undo the four screws (10) at the underside of the unit and lift off the strainer casing (11).
• Pull the individual pump (12) upward and off.
• Pull off the pump lid (13) sideways and pull out the impeller (14).
• Clean all parts under running water.
• For cleaning the nozzle, remove the nozzle holder (15) from the lid with a slight twist.
Reassembling the unit
• Reassemble the unit in the reverse order (E-H).
• Turn the nozzle holder (15) into the lid and plug the pump (12) onto the nozzle.
Note: When inserting the nozzle holders (15) and pumps (12), note the correct order of the numbering (16) in the lid. A
different order will result in a changed water feature and light pattern.
• Ensure the correct seating of the pumps (12), otherwise the strainer casing (11) cannot be closed.
• Lay the cables (17) such that they cannot be crushed. Route the connection cable (18) through the cable lead-through
(19) in the lid.
Storage/overwintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water at a frost-free place. Do not flood the power plug!
Repair
In the event of damage to the cables or the housing, the transformer cannot be repaired and, therefore, has to be re-
placed.
Wear parts
• Impeller unit
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Cause
No mains voltage
Impeller blocked or soiled
Nozzles soiled
Strainer casing soiled
www.oase.com/spareparts
Remedy
Check mains voltage
Check supply lines
Clean impeller
Clean nozzles
Clean strainer casing