Sensor Calibration - Pulsar ACCOLADE LRF XQ38 Instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
8
OPERATION
WARNING!
Do not point the objective lens of the device at intensive sources
of light such device emitting laser radiation or the sun. This may
render the electronic components inoperative. The warranty does
not cover damage caused by improper operation.
WARNING!
The radiator cooling system (12) becomes warm during operation:
this is normal and allows an increase in the sensitivity of the
device.
Powering on and image setup
Open the lens cover
(13)
.
T
urn the
device
on with a short press of the
Adjust the interpupillary distance with the rings (6) by moving the
eyepieces farther or closer to each other.
To obtain a crisp image of the icons on the display, rotate the dioptre
adjustment ring
s (7) Once adjusted,
.
dioptre adjustment ring for distance or any other conditions.
To focus on the object being observed rotate the lens focusing
ring
(8)
.
To set up display brightness and contrast and continuous zoom,
please refer to the
QUICK
A
fter use,
press and
hold down the
off.

SENSOR CALIBRATION

Calibration allows levelling of the background temperature of the
microbolometer and eliminates image flaws (such as frozen image,
vertical stripes etc.).
There are three calibration modes:
manual (M), semi-automatic (SA) and automatic (А).
9
ON/OFF (1)
button.
there is no need to rotate the
MENU FUNCTIONS section.
ON/OFF
button to turn the
Select the desired mode in the menu option "CALIBRATION"
Mode М (manual)
- Close the lens cover, press briefly the ON/OFF (1) button.
- Open the lens cover.
Mode SA (semi-automatic)
- Press briefly the ON/OFF button to calibrate.
- You do not need to close the lens cover (the sensor is closed with the
internal shutter automatically).
Mode А (automatic)
- The device calibrates by itself according to the software algorithm.
You do not need to close the lens cover (the sensor is closed with the
internal shutter automatically).
- In the automatic mode the user can calibrate the sensor with the
ON/OFF (in the SA mode) button.
10
INCREMENTAL DIGITAL ZOOM
The device allows you to quickly increase the basic magnification
(please refer to the
4 times
(XQ models) or
To operate the discrete digital zoom, press successively the DOWN (5)
device
button.
The digital zoom will not be saved after the device is re-started.
11
QUICK MENU FUNCTIONS
The Quick menu allows change of basic settings such as display
brightness and contrast, smooth digital zoom.
Enter the menu with a short press of the М (3) button.
To toggle between the functions below, press successively the M
button.
Brightness
change display brightness from 00 to 20.
Contrast
display contrast from 00 to 20.
"Digital zoom"
line in the specifications table) by 2 or
2 or 4 or 8 times XP models).
(
– press briefly the UP(2)/DOWN(5) buttons to
– press briefly the UP/ DOWN buttons to change
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Accolade lrf xp507741577418Accolade lrfAccolade lrf xq50

Table des Matières