Preparation before using for the first time
Remove all protective packaging and wrapping.
• Check for the completeness of the product. In
case of incomplete delivery and damages. Please
contact supplier (See ==> Warranty).
• Clean all components as described (See ==>
Cleaning and Maintenance).
• Place all the racks inside the appliance.
Operation
• Connect the power plug with a suitable electrical
outlet. Switch on the appliance (if it is included).
Leaving the appliance for running some hours to
• Digital temperature controller operation
1). Setting the temperature
• Press
to enter into the setting mode. The set
temperature is displayed.
• Press
or
to increase or decrease the set
temperature.
• Press
again to confirm the setting and exit.
Then, inside cabinet temperature is displayed.
2). Illumination inside the cabinet
• Press
to switch ON the light. Press
3). Refrigerant LED indicator
• During the cooling operation (compressor ena-
bled), this refrigerant LED indicator will lights up
constantly.
4). Defrost LED indicator
• During the defrost operation, this defrost LED
indicator will lights up constantly.
• Keep the packaging so you can properly store the
appliance when it is not used for an extended pe-
riod of time.
Note: Due to manufacturing residues, the appli-
ance may emit a slight odor in the first few cycles.
This is normal and does not indicate any defect or
hazard. Make sure the appliance is well ventilated.
reach the cooling temperature before placing the
beverage or food inside the appliance.
Refrigerant LED
Defrost LED
°C
Note:
• If no button is pressed within 10 seconds. The
newly set temperature will be stored.
• The temperature setting range from 2°C to 6°C
(233610, 233627, 233634, 233641, 233658, 233665,
233269, 233238) ; The temperature setting range
from 2°C to 8°C (233696, 233290).
• Keep the door open time as short as possible in
order to keep a cool temperature inside.
again to switch OFF the light.
• After the inside cabinet reach the set temper-
ature, the refrigerant LED indicator will flashes
continuously.
• When defrost start, the refrigerant LED indicator
light off.
• After the defrost operation, defrost LED indica-
tor will lights off.
EN