Dimensions; Safety Information; Basic Safety Information; Misuse - Hilti PD4 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
en
Printed: 07.07.2013 | Doc-Nr: PUB / 5070017 / 000 / 00
If measurements are not possible, use the Hilti PDA 50,
PDA 51 or PDA 52 target plate.
Accuracy
±2.0 mm (±1/13 inch) is typical for individual and con-
tinuous measurements **
Smallest unit displayed
1 mm or
1
/
inch
16
** The measuring accuracy is affected by ± (2.0 mm + 20 ppm) /
± (1/13" + 20 ppm) due to atmospheric conditions.
Beam diameter
< 6 mm @ 10 m (< 0.2 inch @ 30 ft)
< 30 mm @ 30 m (< 1.2 inch @ 90 ft)
< 60 mm @ 70 m (< 2.4 inch @ 210 ft)
Basic operating modes
Single measurement
Continuous measurement
Display
Illuminated liquid-crystal display showing distance,
operating and battery status
Laser
Visible, 620 – 690 nm, laser class 2 (IEC825-1; EN 60825-
1); CFR 21 § 1040 [FDA], output power: < 1mW
Automatic time-out
Laser 60 sec.
Range meter: 10 min.
Battery life at 25°C (77°F)
Max. number of measurements on single set of batteries:
Alkaline: 15,000 - 20,000
Operating temperature
- 15°C...+ 50°C (5°F... 122°F)
Storage temperature
- 30°C...+ 70°C (- 22°F... 158°F)
Protection class
Dust tight and waterproof, IP X5 as per IEC529 standard
Weight
180 g (with batteries)

Dimensions

120 (L) × 45 (B) × 28 (H) mm

4. Safety information

4.1 Basic safety information

In addition to the safety precautions listed in the individual
sections of these operating instructions, the following points
must be strictly observed at all times.

4.2 Misuse

The range meter and its accessories can be a source of haz-
ard if they are not used properly or not used for the intended
purpose by untrained people.
• Do not use the range meter without suitable prior instruc-
tion.
• Do not render any safety devices ineffective and do not
remove information and warning notices.
16

Publicité

Table des Matières
loading

Table des Matières