1. Insert the supplied packing nuts A into the fixing holes
on the toilet bowl.
One pair of standard packing nuts with a diameter of
14 mm are included in the package as an accessory
part. If the fixing hole diameter on the toilet bowl
is less than 14 mm other suitable packing nuts and
washers need to be used.
B
A
C
D
1. Put the washers D on both packing nuts.
2. Set in place the brackets B on the catch plate C.
3. Fasten the catch plate with the fixation bolts A through
the brackets in both packing nuts.
C
B
A
1. Screw the PVC flexible hose A clockwise on the inlet
adapter B of the shower toilet.
2. Slide the shower toilet to the catch plate C installed.
CAUTION!
– Make sure that the grooves underneath the
shower toilet are precisely guided in the
recesses of the mounting plate.
B
1. Screw the PVC flexible hose A clockwise on the T-valve
B.
6
A
Attaching remote control holder
A
1. Attach the remote control holder with double stick tape
A on the wall in a suitable location.
Preparing the remote control
A
1. Remove battery cover A from remote control.
2. Insert batteries B. Ensure correct polarity.
3. Close battery cover of remote control.
4. Place remote control D into its holder C.
4.2 Assembling concealed cistern
Installing water flow over angle valve
1. Connect angle valve and bidet with the PVC Flexible
hose (accessory).
2. Turn the water tap on.
IMPORTANT!
– Check the connection for leaks and re-fit if
necessary.
Installing water flow over flush-mounted housing
1. Remove the push plate from the flush-mounted housing.
2. Remove the rear cover plate to obtain a direct
perspective on the connection.
3. Turn the water tap off.
4. Remove connecting sleeve D and replace by T-piece E.
5. Connect T-piece with PVC Flexible hose C.
6. Connect PVC Flexible hose with tube A using nut B.
7. Connect tube A with pure bidet.
8. Turn the water tap on.
IMPORTANT!
– Check the connection for leaks and re-fit
if necessary.
9. Cut-out inner cover plate F, mounting plate G and
push plate H according to the figure above taking into
account the indicated dimensions [mm].
10. Re-attach the inner cover plate and the mounting plate
inside the flush-mounted housing.
11. Close flush-mounted housing with the push plate.