9 Troubleshooting

9.1 Identifying and repairing faults

Fault
Unit does not operate at all
CLEANSING, BIDET, DRY, AUTO do not
operate
Remote control does not operate at all
Malfunction of the remote control
No water spray
Low water pressure
Low water temperature
Seat is not warm
Dryer air is not warm

10 Technical Data

10.1 General data

Power supply
Max. power consumption
Intermittent (periodic
operation)
Type of protection, entire
device
Length of power cord
Battery type remote control
Type water supply
connection
Ø Connection at shower
toilet
Ø T-piece
Ø Connection hose
Length connection hose
Water supply pressure
12
Possible cause(s)
Power is off
Power plug is not connected
There is a power failure
Seat is covered
Batteries in the remote control have
been exhausted
Batteries are empty or too weak
Remote control out of reach of the
device
The shut off valve is closed
There is water supply outage
The water pressure level is set to "LOW" Increase water pressure level,
The water strainer is clogged
Nozzle head is dirty
The water temperature level is turned
off or set to "LOW"
The warm seat temperature level is
turned off or set to "LOW"
The warm air dryer temperature level is
turned off or set to "LOW"
220 – 240 V AC, 50/60 Hz
1725 – 2053 W
85%, 30 min. ON / 5 min.
OFF
IPX4
1)
1.4 m
2 x AA (LR6) / 1.5 V
Direct connection to the
water supply
1/2"
1/2"- 3/8" - 1/2"
1/2" cranked to 3/8"
500 mm
79 – 735 kPa
Remedy
Press any button to check except "HIGH",
"LOW", "FRONT" or "BACK" buttons of
the remote control.
Make sure that there is nothing on
the seat surface. (The device is only
activated when the user's skin touches
the seat sensor.)
Replace batteries with new ones,
→ 4.1 Installation / Assembly, page 5 .
Replace batteries with new ones,
→ 4.1 Installation / Assembly, page 5 .
Open shut off valve.
Restore water supply.
→ 5.3 Using the shower toilet, page 8 .
Clean water strainer, → Cleaning, page
10.
Clean nozzle, → Cleaning, page 10.
Turn on or increase water temperature
level,
→ 5.3 Using the shower toilet, page 8 .
Turn on or increase seat temperature
level,
→ 5.3 Using the shower toilet, page 8 .
Turn on or increase warm air dryer
temperature level,
→ 5.3 Using the shower toilet, page 8 .
Water supply temperature
Operating temperature
Product width
Product length
Product depth
Product weight
Cleansing functions
Water flow rate CLEANSING
Water flow rate BIDET
Water pressure adjustment
Temperature adjustment
Heater capacity
Safety devices
Warm seat
Temperature adjustment
3 – 25 °C
3 – 40 °C
389 mm
515 mm
156 mm
3.9 kg
0.7 l/min
0.85 l/min
3 levels
Normal water supply
temperature,
34 °C, 37 °C, 40 °C
1670 – 1987 W
Thermal fuse, Thermostat
Room temperature, 35 °C,
38 °C, 40 °C
1590625-F