electrical information

EN

3.2 hard wiring installation

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualifi ed service person should service
and repair this electric appliance.
Hard Wiring Connection
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must rated for 120V minimum 15
amps.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
note:
There are 6 wires from the appliance junction box: 1 green (G), 1 white (N), 1 blue (N1), 1 gray (N2), 1 black (L1),
and 1 red (L2).
14
W415-1767 / C / 01.29.18
240V HARD WIRING INSTALLATION
FIREPLACE
JUNCTION
TERMINAL BLOCK
WHITE
N
N1
BLUE
N2
GRAY
L1
BLACK
L2
RED
G
GREEN
120V HARD WIRING INSTALLATION
FIREPLACE
JUNCTION
TERMINAL BLOCK
WHITE
N
N1
BLUE
JUMPERS
N2
GRAY
L1
BLACK
L2
RED
G
GREEN
CONNECT TO
240V POWER
SUPPLY MIN.
15AMPS
NEUTRAL
L1
L2
GROUND
W385-2233
W385-2233
CONNECT TO
120V POWER
SUPPLY MIN.
15AMPS
NEUTRAL
L1
GROUND
W385-2232
W385-2232