Troubleshooting Guide - Shindaiwa PB 3410 Manuel D'utilisation

Balai motorisé
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting Guide

What To Check
Does the engine crank?
YES
Good compression?
YES
Does the tank contain fresh
fuel of the proper grade?
YES
Is fuel visible and moving
in the return line when
priming?
YES
Is there spark at the spark
plug wire terminal?
YES
Check the spark plug.
16
ENGINE dOES NOT START
Possible Cause
Faulty recoil starter.
NO
Fluid in the crankcase.
Internal damage.
Loose spark plug.
NO
Excess wear on cylinder, piston,
rings.
Fuel incorrect, stale, or contaminated;
NO
mixture incorrect.
Check for clogged fuel filter and/or vent.
NO
The ignition switch is in "O" (OFF) position.
NO
Shorted ignition ground.
Faulty ignition unit.
If the plug is wet, excess fuel may be in the
cylinder.
The plug is fouled or improperly gapped.
The plug is damaged internally or of the
wrong size.
Remedy
Consult with an authorized servicing
dealer.
Tighten and re-test.
Consult with an authorized servicing dealer.
Refill with fresh, clean unleaded gasoline
with a pump octane of 87 or higher mixed
with 50:1 Shindaiwa Premium 2-cycle
mixing oil or with an equivalent high
quality 2-cycle mixing oil.
Replace fuel filter or vent as required.
Restart.
Move switch to "I" (ON) position and restart.
Consult with an authorized servicing dealer.
Crank the engine with the plug removed,
reinstall the plug, and restart.
Clean and regap the plug to .024" / 0.6mm-
0.7mm. Restart.
Replace the spark plug. Check the
"Specifications" section for the correct plug
for your unit. Restart.

Publicité

Table des Matières
loading

Table des Matières