OBJ_BUCH-0000000248-001.book Page 7 Monday, February 1, 2016 2:20 PM
Emission values for sound and vibration (Two-figure – specifications as per ISO 4871)
Sound emission
A-weighted emission pressure power level measured at
L
the workplace
(re 20 μPa), in decibels
pA
K
Measuring uncertainty
Measured A-weighted sound power level
in decibels
K
Measuring uncertainty
C-weighted peak sound pressure level measured at the
L
workplace
, in decibels
pCpeak
Measuring uncertainty
K
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
Vibration
Classification of FEIN
application tools accord-
ing to vibration class
VC0
VC1
VC2
VC3
VC4
VC5
a
K
* These values are based on a work cycle consist-
ing of no-load and full-load operation of the same
duration.
For information on the vibration class assigned to
the application tool, please refer to the enclosed
data sheet 3 41 30 443 06 0.
, in decibels
pA
L
(re 1 pW),
wA
, in decibels
wA
, in decibels
pCpeak
Weighted
When using the large round sanding plate
acceleration*
(No. 63806195210, Ø115 mm) or the cleaning
kit for tile joints (No. 63719011220), the
2
< 2.5 m/s
damping system can be subject to overload
2
< 8 ft/s
due to the heavy weight of the accessories.
This becomes apparent through unpleasant
2
< 5 m/s
and very intense vibration of the machine.
2
< 16 ft/s
Corrective action: Reduce the speed of the
2
< 7 m/s
machine to electronic level 2.
2
< 23 ft/s
Due to the then possibly reduced working
progress, the machine is only suitable to a
2
< 10 m/s
limited extent for above mentioned accesso-
2
< 33 ft/s
ries.
2
< 15 m/s
2
< 50 ft/s
2
> 15 m/s
2
> 50 ft/s
2
1.5 m/s
2
4.91 ft/s
AFMT12 (SL) AFMT12QSL (SL)
70
3
81
3
83
3
Possible overloading of the vibration
damping with especially heavy accesso-
ries!
en
7
70
3
81
3
83
3