2. Installation of the unit
2.1 Suspension of the CDF 10 unit
The wall suspension bar supplied with the unit is fixed to the wall and the dehumidifier is hung up on it. It is
important to mount the unit in a horizontal position to secure correct outflow of the condensate water.
The dehumidifier must be placed in a way that allows unimpeded air intake through the front and outlet through the
grill on the sides. Be sure always to leave at least 100 mm free space around the unit for optimum operation.
It is important that the dehumidifier is not installed near a source of heat as for example a radiator, and doors and
windows must be kept closed when the dehumidifier is in function.
2.2 Condensate outlet
The condensate outlet is located at the bottom of the dehumidifier. The unit has a drain spigot intended for
connection of a ½'' flexible or fixed water connection. If water drain through the wall is chosen, a suitable hole is
made in the wall and the condensate hose is led out through this hole, before suspending the dehumidifier on the
wall suspension bar.
As an alternative a condensate pump can be fitted at the water outlet to pump the water to a drain.
The placing of the condensate outlet is shown on the drawing below.
NOTE! On the rear of the unit a cable binder protects the compressor
during transport. This cable binder must be removed before
suspension and power connection.