Prior to operating your new char broiler, thoroughly wash the exterior with a mild detergent or soap solution. Do
not use abrasive cleaners, since this might damage the cabinet finish. If the stainless steel surfaces become
discolored, scrub by rubbing only in the direction of the finished grain.
When the char broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust from
storage and shipping are burned off. An hour at "max." on all burners is usually sufficient.
DAILY CLEANING:
Remove the grease pan, empty and wash it.
Grate "burn off'. The grease buildup on the grates should be cleaned daily (more often as needed).
1. Caution: When handling grates or radiants, always use insulated gloves to prevent burns.
2. Warning: Do not cover the top of the grid grates during a burn off operation. Restricting the airflow by
covering the grid grates may cause them to warp. It will also cause damage to the valves, the knobs and
the front panel decal.
3. Place grates on broiler, with grid bars horizontal, facing down.
4. Turn the char broiler on for approximately 45 minutes.
5. Turn off the char broiler and allow it to cool for 20 Minutes.
6. Clean top and bottom surfaces of grate with a wire brush to remove animal fats and carbonized grease.
7. Clean channels on grates with a scraper.
8. Remove grates from char broiler. Clean top surface of radiants with the wire brush. They may be cleaned in
place.
NOTE: Parts protected by the manufacturer or his agent are not to be adjusted by the installer, unless
the installer is an authorized service agent.

Troubleshooting

TROUBLESHOOTING GUIDE

PROBLEM
Heat does not come on when valve
is turned on.
Pilot burner will not light.
Pilot burner will not stay lit.
Pilot burner not lit.
Gas valve is bad.
Obstructed pilot orifice.
Pilot valve turned off.
Obstructed pilot orifice.
Gas supply is not purged of air.
Air is blowing pilot light out.