General Installation Instructions - Omcan CE-CN-CBR15 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

d. Install the converter cover to the regulator.
Note: The arrow in the regulator indicates the flow direction of the gas.
8. Re-install the U burners.
9. Check leakage and re-install other parts.
10. Ignite the pilot burner and check flame state.
Turn the knobs to "High".
If the U burner does not ignite, open the pilot valve more.
If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame should
be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs are
turned to "|".
Note: Please check leakage before re-install the control-panel.

GENERAL INSTALLATION INSTRUCTIONS

Ensure gas supply and gas type, as shown on unit nameplate, agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National
Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in
accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level
the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if
necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and
water solution before operating unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE
SURFACES ONLY.
For use in non-combustible locations only.
For use only on non-combustible countertops.
Non-combustible and unit clearances: 0" (0mm) sides and rear | 4" (102mm) floor.
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the
flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects between
the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners are
removable thru the front if the gas line is disconnected.