Operation
Note: The cycle starts from the time the appliance is initially powered up.
To manually defrost the appliance:
1. Press and hold the DEFROST
2. The defrost cycle will start immediately and the Defrost LED illuminates. The defrost will last 20 minutes.
Note: Starting a manual defrost also resets the automatic defrost timer. The next automatic defrost will
start 12 hours after the manual defrost has finished.

Maintenance

ROUTINE MAINTENANCE

Switch off and disconnect from the power supply before cleaning.
Clean the enclosure and interior of the appliance as often as possible.
Wash the unit with moist cloth. Never allow the switch, control panel, cable or plug to get wet.
Do not use abrasive cleaning agents. These can leave harmful residues. Use only mild soapy water.
Ensure that no cleaning water penetrates into the electrical components.
Must not be cleaned by a water jet.
Always wipe dry after cleaning with soft cloth.
Take care when cleaning the rear of the appliance.
An agent or qualified technician must carry out repairs if required.
If the appliance is to be left inactive for long periods, unplug the appliance after having turned the switch to
OFF position, empty the refrigerating compartment and clean thoroughly.

SPECIAL MAINTENANCE

The instructions given in the following paragraph are for SKILLED PERSON.
Periodically clean the condenser using suitable tools ( vacuum cleaner or soft brushes).
Check that the electrical connections are not loose.
Check that the thermostat and the sensor are in proper working order.
Recommend that an agent or qualified technician clean the condenser.
button for 5 seconds.