G
®
AERASGARD
RCO
The self-calibrating microprocessor-controlled AERASGARD
detect the CO
content in air within a range of 0 ppm to 2000 ppm CO
2
measurement signals from the CO
signals of 0 -10 V. Optionally, this CO
with display or switching output. Elegant enclosure made of plastic, with snap-
on lid, base with 4-hole attachment for installation on vertically or horizontally
installed in-wall flush boxes, with predetermined breaking point for on-wall ca-
ble entry. or in enclosures made of stainless steel (top and bottom part are of
stainless steel, the lid is screwed on), van dalism-secure version e.g. for
schools, military barracks, and public buildings. The CO
mined by a NDIR sensor (non-dispersive infrared technology). The detection
range of this CO
sensor is calibrated for standard applications such as moni-
2
toring of residential rooms or con ference rooms. Room ventilation on an as-
needed basis, improvement of well-being and customer benefit, increased
comfort as well as a reduction of operating costs by energy conservation are
only some of the beneficial results of employing AERASGARD
TECHNICAL DATA:
Power supply: .............................. 24 V AC ⁄ DC
CO
sensor: ................................. optical sensor (NDIR),
2
Measuring range, CO
: .............. multi-range switching (selectable via jumper)
2
Output CO
: ................................. 0 -10 V
2
Measuring accuracy CO
: ......... ± 100 ppm
2
Pressure dependence: .............. ± 1.6 % ⁄ kPa (referred to standard pressure)
Long-term stability: .................... ± 1 % of final value per year
Service life: .................................. > 12 years
Gas exchange: ............................. by diffusion
Warm-up time: ............................ ca. 1 hour
Ambient temperature: .............. 0 ...+50 °C
Electrical connection: ................ 0.14 - 1.5 mm
Enclosure: .................................... plastic, material ABS,
Dimensions: ................................. 98 x 106 x 32 mm (Frija II)
Installation: .................................. wall mounting or on in-wall flush box, Ø 55 mm,
Protection class: ........................ III (according to EN 60 730)
Protection type:.......................... IP 30 (according to EN 60 529)
Standards: ................................... CE-conformity,
Type ⁄ WG1
Measuring Range
CO
2
RCO
0 ... 2000 ppm
2
RCO
- U
0 ... 2000 ppm ⁄ 0 ... 5000 ppm ⁄ 0 ... 10000 ppm
2
xx - Stainless steel
Note:
This unit must not be used as safety-relevant device!
2
transmitter are converted into standard
2
measuring transducer can be supplied
2
content in air is deter-
2
non-dispersive infrared technology
0 ... 2000 ppm; 0 ... 5000 ppm;
0 ... 10000 ppm
2
, via terminals on circuit board
colour pure white (similar RAL 9010),
stainless steel enclosure optional
100 x 100 x 25 mm (stainless steel enclosure)
base with 4-hole for mounting on vertically
or horizontally installed in-wall flush boxes for
cable entry from the back, with predetermined
breaking point for on-wall cable entry from
top ⁄ bottom in case of plain on-wall installation
electromagnetic compatibility
according to EN 61 326 + A1 + A2,
EMC directive 2004 ⁄ 108 ⁄ EC,
low-voltage directive 73 ⁄ 23 ⁄ EEC
®
RCO
is used to
2
Connecting diagram
. The
2
Connecting diagram
®
RCO
sensors.
2
Schematic diagram
manu/auto
set CO
CO
2
(measuring range adjustable)
0 ... 2000 ppm (default)
0 ... 5000 ppm
0 ... 10000 ppm
Output
0 -10 V
0 -10 V
1
UB+ 24V AC/DC
2
UB- 24V AC/DC
3
Free
4
Free
5
GND
6
Free
7
Free
Output CO
content in ppm 0-10V
8
2
1
UB- GND
2
UB+ supply voltage 24V AC/DC
3
Output CO
content in ppm 0-10V
2
CO
probe
2
3
2
2
CO
range
2
content
RCO
2
RCO
- Display
2
RCO
- Display
2
1
JP
JP
JP
1
2
3