READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
HOW TO USE THE LCD
DISPLAY DURING NORMAL OPERATION
Safety
Activation
Stall
(door 1 & 2)
FACTORY VALUE VS. SAVED VALUE
NAVIGATING IN MENUS
Push to enter
the LCD menu
CHANGING A VALUE
SCROLL MENU
UP/DOWN
LED STATUS
75.5753.14 LZR-MICROSCAN T 20180208
75.5753.14 LZR-MICROSCAN T 20180208
Negative display = active output
Opposite for reverse logic
displayed value = factory value
Select Back to return
to previous menu or
display.
current value is
displayed
PUSH
TO SELECT
PARAMETER
COLOR
SIGNAL
Blue
Learn
White
Tracking
Orange
Home Switch
COLOR
SIGNAL
Green
Operational
Red
Detection
Orange*
Error
Select your language before entering
the first LCD menu.
Available for the first 30 seconds after
power-on of the hub.
more values are
SCROLL VALUES
UP/DOWN
HUB LED
DESCRIPTION
Learn in progess or Learn required
Door position & detection zone tracking
Home Switch closed (door closed)
SENSOR LED
DESCRIPTION
Sensor operational
Sensor in detection / Sensor monitoring
Sensor in error...reference hub LCD
* see TROUBLESHOOTING section for descriptions of orange LED error indications
To adjust contrast, push
and turn the gray button
simultaneously.
During normal operation only.)
displayed value = saved value
Select More to go to
the next level:
- basic
- advanced
- diagnostics
displayed
PUSH TO SAVE
NEW VALUE
Scroll menu
items
new value is
displayed
Page 3 of 16
Page 3 of 16