WIRING
IMPORTANT:
• All wiring harnesses used must a) be routed separate from any mains or non-class 2 voltage cables,
or b) be rated for the mains voltage and suitable protection.
• Routing means must be used in accordance with national and local codes.
DOOR TYPE
single
simultaneous
pair
dual-egress
Power
1
Most doors require the use of the LZR-microscan T Power Supply.
For information on powering directly from door control see Tech Bulletin #53.
1a
If using door control power,
connect Power Supply Harness to
door control.
3
Plug Power Supply or Power
Supply Harness into hub port
labeled Power.
External Monitoring
LZR-microscan T hub/sensors are intended to be monitored by the door system for proper operation (see Tech Bulletin
#53).
If the door control does not utilize monitoring, do not use monitoring wires.
If utilizing the monitoring function, the sensor LED will briefly flash RED during monitoring communication with door
control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor
and monitoring wires must be properly connected to the door control.
Page 8 of 16
Page 8 of 16
always use DOOR CONTROL A hub port
from header cover side, left door uses DOOR CONTROL A hub port and
right door uses DOOR CONTROL B hub port
from header cover side, whichever door is pushed (right door) during Teach
In process uses DOOR CONTROL B hub port
1b
If using BEA-provided power
supply, cut plug off of harness,
and strip wires.
NOTES:
HUB PORT
Power
Supply
2
1. LZR-microscan T hub/sensors must be powered by a UL Class 2 power
supply limited to 15 W.
2. If a NEMA 5-15R outlet is not available in door header, cut off
NEMA 5-15P plug and wire-nut to 110 VAC observing polarity and
grounding. By cutting off plug, system changes from UL-Listed to
UL-Recognized.
2b
Wire-nut input of power supply to
110V power source.
75.5753.14 LZR-MICROSCAN T 20180208
75.5753.14 LZR-MICROSCAN T 20180208