10.3. Start the programming
Action
Only during programming, record
options,
option 4:
Switch programming mode of the
installation on and off again
activate device's programming mode
Enter master code
(Start programming within 2 min.!)
Correct code
Wrong code, master code unknown
No code entered
10.4. Programming
Determine / change access cod
First access code
second access code
etc.
Activate / deactivate relay for code
Send protocol when determining the
code input
Delete dataset
(for a certain
memory location)
EN
Description
(FI = 0)
On the power supply and control unit:
• press RUN/PROG key briefly, LED flashes.
• press RUN/PROG key briefly, LED is on.
On the 10-363:
Two-tone LED flashes green during 2 min.
Input:
Mastercode
(FI = serial number of the code lock module)
During 3 sec. a positive confirmation tone sounds (one long beep), LED flashes
green (2 min).
The device can now be programmed.
If you press
a negative confirmation tone sounds (three beeps). You have only
3 opportunities to enter the wrong code, otherwise the code entering function will
be blocked during 2 min.
Start again.
If after 2 min. no command has been entered, the device will automatically
terminate the programming mode. The LED will also switch off.
Input:
0
memory location number 1
Invoer:
0
memory location number 2
Memory location number = 1 to 10
Access code = max. 8 digits (1 to 8 digits)
When changed, the old code is overwritten by the new one.
Input:
1
memory location number
Memory location number = 1 to 10
(FI = 1 for MlNo 1 to 10)
R =
1 ON
0 OFF (relay without function)
Input:
2
memory location number
Memory location number = 1 to 10
(FI = 0 for MlNo 1 to 10)
P =
0 (door opening protocol with own ExtU address)
1 (Control function 1 with own serial number)
2, 3, 4, 5 Free protocols
6 (MlNo with own serial number)
7 (Don't send protocol)
Input:
memory location number
Memory location number = 1 to 10
.
access code
access code
R
P
10-363
G
G
access code
access code
R – relay function
P – protocolkeuze