Other application examples
Starting/stopping (CINH) with the function module Standard−I/O
Switch/potentiometer unit
CINH
Controller inhibit
Wiring for start/stop through switch
Terminal assignment
X3/20
Yellow wire
DC supply +20 V
Starting/stopping (CINH) with the function module Application−I/O
Switch/potentiometer unit
CINH
Controller inhibit
Wiring for start/stop through switch
Terminal assignment
X3/20
Yellow wire
DC supply +20 V
)
Note!
Instead of using X3/28 also digital input (X3/E1 ... X3/E6) can be connected
and thus different digital functions, e.g. JOG1 on E1, can be activated.
EDK82ZBU DE/EN/FR 4.0
Electrical installation
Other application examples
/CINH
X3/28
Grey wire
Start/stop
/CINH
X3/28
Grey wire
Start/stop
11
Wire bridge
Controller enable
Pink wire = not used
Appropriate insulation!
Controller enable
Pink wire = not used
Appropriate insulation!
l