0Fig. 0Tab. 0
1
Preface and general information
These Instructions
ƒ describe the installation and handling of the switch/potentiometer unit.
ƒ are only valid
– for switch/potentiometer units with the nameplate data E82ZBU
– together with the Operating Instructions of the corresponding controller.
Description
The switch/potentiometer unit E82ZBU enables
ƒ the selection of an analog setpoint signal for Lenze controllers through the function
modules Standard−I/O and Application−I/O.
ƒ easy control of Lenze controllers through digital inputs of the function modules
Standard−I/O and Application−I/O (e. g. reversal of direction of rotation).
Range of application
To be used with 8200 motec frequency inverters as of nameplate label
E82MVxxx 4Bxxx 0x0x
Scope of supply
Qty.
Description
1
Switch/potentiometer unit with pre−cut 2.5 m connection cable
1
Mounting sheet 60 mm x 60 mm
4
Screws M4 x 30 for mounting the switch/potentiometer unit to the mounting sheet
2
Screws M4 x 20 with spring steel sheet for mounting to the heatsink of the motec
General data and application conditions
Type of protection
Dimensions (W x H x D)
Possible mounting positions
EDK82ZBU DE/EN/FR 4.0
Preface and general information
IP65
approx. 65 mm x 115 mm x 85 mm
Mounting to the heatsink of a
motec
Mounting to a wall
7
l