Télécharger Imprimer la page

Ecolab 5L10X Manuel De L'utilisateur page 2

Applicateur de mousse de 5 l

Publicité

Les langues disponibles

Les langues disponibles

User Manual | ECOLAB 1.3 Gal Pump-Up Foamer | English
WARNING
Read and understand this manual before operating, servicing, or interacting with the equipment.
• Chemical products can be harmful to your and your surroundings. Know the hazards of your chemical product prior to use.
Follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data
Sheet (SDS). Always wear appropriate personal protective equipment (PPE) for your chemical product.
• Never use with hydrocarbons or flammable products.
• Never exceed a fluid temperature of 100˚F (37˚C).
• Always flush unit thoroughly with fresh water before switching from an alkaline product to an acid product or vice versa.
• Never point the discharge wand at yourself, another person, or any object that could be damaged by chemical exposure.
• Always depressurize unit before attempting to remove the pump assembly.
• Always depressurize unit after use. Always store unit depressurized.
• Do not pressurize unit by any means other than the built-in pump assembly.
• Never leave unit unattended while pressurized.
• Do not modify or remove pressure relief valve. Do not use unit if pressure relief valve is not operational.
• Do not modify or service unit with parts not listed in this manual. If this unit is modified or serviced with parts not listed in
this manual, the unit may not operate correctly.
• Keep this manual for reference.
PROTECT THE ENVIRONMENT
Dispose of packaging materials, equipment components, and chemical products in an environmentally safe way
according to applicable waste disposal regulations. Always recycle when appropriate.
REQUIREMENTS
Liquid temperature
40-100˚F (4.4-37˚C)
range
Chemical
Chemical products used with this
compatibility
equipment must be formulated for
this type of application and compatible
with unit materials and pump seals.
For more information on chemical
compatibility, consult the manufacturer
or SDS for your product or contact our
customer service department.
SPECIFICATIONS
Power type
Manual
Chemical pickup type Draws from pre-mixed solution
Number of products
One product
unit can draw from
Capacity
1.32 gallons (5 liters)
Discharge hose
4 ft. (1.2 m) hose with 1/4 in. (6.35
diameter/length
mm) inside diameter
Discharge wand/tip
Polypropylene trigger handle with
interchangeable tubing tip and 110˚
type
fan tip
2-3 ft. (0.6-0.91 m) with fan tip
Output distance
EPDM, Aflas, Viton
Pump seals
Operating pressure
35 psi (2.4 bar) or below
Manual Part Number: 9215 3309
Manual Form Number: 47357_5400_0814
Failure to comply with the instructions and safety precautions in this
manual could result in death, serious injury, and/or property damage.
Information in this manual is subject to change without notice.
REPLACEMENT PARTS
5
4
7
PRODUCT CODE
DESCRIPTION
ID
8999 2179
HOSE ASSEMBLY (INCLUDES SUCTION LINE)
1
8999 2180
PUMP ASSEMBLY
2
8999 2181
SPRAY GUN ASSEMBLY (INCLUDES WADDING #8)
3
8999 2182
WAND EXTENSION
4
8999 2183
VEEJET NOZZLE - PVDF 110 DEGREE 0.8 GPM
5
6
8999 2185
NATURAL 5 LITER TANK WITH PRESSURE GAUGE
8999 2186
TUBING EXTENSION TIP - 18 INCH LENGTH
7
8999 2187
WADDING FOR SPRAY GUN - 3/4 INCH DIAMETER
8
2
Carrying Handle
Pressure Relief Valve
Air Pressure Gauge
6
3
1
Page 2 of 2