Leuze electronic MSI 200 Manuel De L'utilisateur page 23

Masquer les pouces Voir aussi pour MSI 200:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

General data
Electrical isolation
Surge protection
Air and creepage distances between the circuits
Rated voltage
Rated surge voltage
Pollution degree
Surge voltage category
Mounting position
Housing material
Dimensions (W/H/D)
Conductor cross-section
Safety characteristic data
Category
Performance level
SILCL
Safety Integrity Level (SIL)
Parameters
MTTF
D
DC
Parameters
as per IEC 61508 (EN 62061)
PFH
Proof test interval (T
1
1)
No capacitive load must be taken into account when using electromechanical components
(e.g. contactors).
2)
A suitable and effective protective circuit is to be provided for inductive loads.
One recommended measure is the use of free-wheeling diodes.
3)
Specifications are applicable only if the safety function is requested at least once a year.
4)
Since all diagnostics tests are carried out during operation, the service life for the proof test interval
is adopted.
Derating curve:
screw connection
spring-cage connection
screw connection
spring-cage connection
as per EN 954-1
as per EN ISO 13849-1
as per EN 62061
as per IEC 61508
as per EN ISO 13849
)
[months]
2
1,5
1
0,5
0
0
25 30 35 40 45 50 55 60
Yes, between power supply for logic
(A1/A2) and power supply for safe outputs
(24 V/0 V)
Suppressor diode
As per DIN EN 50178:1998-04 1
basic insulation
50 V
0.8 kV
2
III
Horizontal
Polyamide PA, non-reinforced
(67.5/114.5/ 99) mm
(67.5/114.5/112) mm
0.2 - 2.5 mm
0.2 - 1.5 mm
4
e
3
3
3)
[years]
8321 (high)
99 % (high)
3)
-8
[1/h]
1.37 x 10
4)
240
Ambient temperature [°C]
2
(AWG 24-12)
2
(AWG 24-16)
23

Publicité

Table des Matières
loading

Table des Matières