Operation and use

Normal operation: Using TSA+ or similar remote controls.
Obstacle detection operation: When an obstacle is detected during the open cycle, the door will stop (1). When an obstacle is detected during the close
cycle, the door will stop and then reopen (2). Once an obstacle has been detected, the light will fl ash for 30 seconds.
1)
Light operation: The light will come on each time the motor drive unit is operated. The light will go out one minute after the door stops moving. Repetitive
use that causes the light to be continually on may result in a thermal cut out (this will automatically turn the light off).
Manual release cord operation: The GM800 is fi tted with a manual release mechanism so that you can move the door manually should a power failure
occur, for example. The manual release mechanism should be easily accessible and located no more than 1.80 metres above fl oor level.
1- Disengaging the motor drive mechanism: Pull on the manual release cord until the door drive mechanism is disengaged.
2- Manually moving the door: This is possible as long as the door drive mechanism is disengaged.
3- Reengaging the motor drive mechanism: Move the door manually until the drive mechanism comes to reengage itself into the transmission rail.
1
When disengaging the motor drive mechanism, use caution for a badly balanced door may cause sudden door movement that may be dange-
rous. Only use the cord to disengage the motor drive mechanism. Never use the cord to move the door manually.
Always reengage the motor drive mechanism before sending another command to the motor drive unit.
Special operations: Depending on the peripherals installed and the operating options set by your installer, the gm800 operator may perform the following
special operations:
- Using "COLOR+" or similar remote controls:
- Safety photoelectric cell operation: An obstacle detected between the cells will prevent the door from closing. The door will stop and then reopen when
an obstacle is detected during the close cycle. The light will fl ash for 30 seconds during this process.
- Pedestrian door safety function: Opening a pedestrian door within the garage door will prevent the door from moving. The light will fl ash for 30 seconds
during this process.
- Flashing amber light: The amber light comes on whenever the door moves, with a two second advance warning before the start of door motion.
- Working from the back-up battery: If a back-up battery is installed, the GM800 motor will operate when a power cut occurs. The following conditions
apply to operation:
- Door speed is reduced.
- The light will not come on.
- The safety devices are disabled.
Battery specifi cations:
- Endurance: the battery will last for 24 hours with a maximum of 5 to 10 operating cycles depending on the weight of the door.
- Charging time: 48 hours.
- Service life prior to replacement: approx. three years. To ensure optimum battery life, we recommend that the power to the motor is switched off and the
door is operated for a number of cycles using battery power (three times a year).
- "forced operation" mode: This function is used to move the door at any time (remote control lost, safety mechanism failure, etc.). Remove the built-in
lighting cover and control door motion using the
Pressing and holding the
10
2)
2
and
button will trigger opening.
3
buttons. Pressing and holding the
OFF
1 min.
CLAC!
OFF
1 min.
button will trigger closure.