Adjusting and fastening the opening travel stop
1- Release the trolley from the runner using the
manual release mechanism and bring the
door to the open position. Do not open the
door fully, but position it so that it does not
reach its own travel stop.
2- Slot the travel stop into the rail then turn it by
90°.
3- Position the travel stop against the trolley.
4- Moderately tighten down the mounting screw.
Do not tighten the mounting screw all the way down. Excessive tightening can damage the screw and cause the travel stop
not to remain in place. Do not use the travel stops supplied with the transmission rail.
Fitting the chain retainer pads
(for chain rails only.)
These pads are used to limit spurious noise linked
to chain friction within the rail.
1- Position each of the pads in the fi rst hole in the
rail after the travel stop.
2- Make sure that the pad is pressed in all the way
so that its positioning pin is accessible outside
of the rail.
Checking the chain or belt tension
- The rails are supplied ready tensioned and inspected. If necessary, adjust the tensioning.
The rubber or tension spring must never be full compressed during operation.
Connecting the mains power
supply
1- Remove the motor cover and the
protective sheet.
3- Fit the light bulb.
4- Connect to the mains supply.
Plug the power cable into a suitable power outlet that complies with electric power requirements. The electric supply must be
suitably protected (a fuse or circuit breaker with a 5 A rating) and a residual current device (30 mA).
An omnipolar disconnection mechanism must be provided for the power supply:
- by using a power cord with a mains splug that can be disconnected, or
- by fi tting a switch that ensures a contact separation distance of at least 3 mm for each pole (refer to standard EN60335-1).
Make sure that the manual release cord is located at a maximum height of 1.80 metres off the ground. If necessary, extend the cord.
5
Setting and programming
Programming keyboard description
Operation indicator light (red)
End limit setting and self-learning
indicator light (green)
P0 - P1 parameters indicator (green)
Indicator light key
off
flashing
1
1
on
2
90°
1
2
Press for 0.5 s: call up and exit the setup menu
Press for 2 s: start self-learning
Press for 7 s: clear self-learning and settings. Stop self-learning
Modifying a setting value
Controls the "forced mode"
3
2
17 mm
3
Press for 2 s: memorise remote controls
ress for 7 s: delete remote controls
4
3
5