Charger connected to the vehicle and
time schedule but not load
The protections of the installation are
triggered
After manual deactivation or with RFID
card the load does not stop and the
intake is blocked
The charger could not connect to a
WiFi network
After the loading process, the charger
remains connected to the vehicle with
the locked pin, fixed green status bar
Exceeding maximum power
If the time scheduling indicator is on
(
), pass the RFID card to activate the
time schedule.
If the time scheduling indicator is off, the
vehicle does not support external time
programming. Schedule the time interval
on the vehicle itself, and delete the loader
schedule.
If the charge modulation indicator is off,
the TMC100 is not properly connected.
Check
connection
direction of current and that the TMC100
is well closed, as indicated in the Load
Modulator section.
If the charge modulation indicator is
on,
the adjusted power does not
match the contract.
Release and disconnect the vehicle hose.
If it has been activated with an RFID card,
check that it is the same one that was
used in the activation or that it is
authorised.
If
release and disconnect the vehicle hose.
If the WiFi indicator
not go to fixed target, it is because the
charger has not been correctly configured
or the correct password has not been
entered.
If the WiFi indicator is blinking blank, it's
because it's connected to an unconnected
WiFi network or the network security is
blocking it.
Reset: Rearm the protections and restart
the charger to remove the pin.
The modulator hasn't worked.
Check the configuration according to the
power contracted.