Maintenance
The equipment is designed in such a way that maintenance will be much lower
because of the long life of its components. Maintenance will be limited to
cleaning the equipment, checking the operation and verification of the input
voltage values and differential protection. The equipment should undergo a full
inspection once a year.
In order to clean and check the equipment connections, it is very important that
it is disconnected from the power supply. Any operation that requires the
opening of the equipment must be carried out by personnel with the correct
technical qualifications and who is authorized to do so.
Technical features
Power supply
Nominal frequency
Power
Consumption
Recharge modes (as per model)
Outlets
Wi-Fi connection
Casing lock
Degree of protection
Degree of mechanical protection
Torque
Stripping length
Working temperature
ATTENTION: This is a product with an embedded battery. Do
not dispose of the product without taking the precaution of
dismantling the battery and depositing it in a suitable recycling
container
|
| According to features label
|
Empty: 5 W (16 VA)
Charging function: 9 W (16VA)
Modes 1 and 2 according to EN 61851-1
Mode 3 according to EN 61851-1
For charging modes 1 and 2: according to
UNE 20315-1-2 fig. C2a (Schuko)
For charging mode 3: according to EN
62196-2 Type 2
802.11 b/g/n
Using a key lock
IP54
IK08
min. 1,2 Nm - max. 2,4 Nm
12 mm
-30 ºC to +50 ºC
19