Single-phase or three-phase connection
TMC100-
-
TMC100+
Connect the output of the TMC100 to the plug-in terminal block connector
supplied and connect to the VIARIS COMBI control circuit.
Must be used twisted pair cable with section 0.25-0.5 mm², maximum
length 1000 m, with a peeling of 6-7 mm, and torque of 0.2 Nm.
Connect the TMC100 Bus to the control circuit of the VIARIS COMBI through
the embedded plug-in connector. Adhere to the indications in the image so that
the measurement is correct.
TMC100 +
TMC100 -
L
TMC100-
TMC100+
L3
3
-
+
11
L2
2
-
+
L1
1
-
+