Load modulator operation
The load modulator will take into account the household consumption and
adjust the power demand to achieve the fullest recharge in the shortest time
possible without exceeding the rated power. In VIARIS COMBI with two outlets,
the load modulator distributes the available energy between the two outlets.
TMC100
Couple/clamp the TMC100 transformer (included) to the phase conductor (L)
so that it measures the total consumption of the installation, including that of
the VIARIS COMBI.
RESPECT THE SENSE OF THE CURRENT INDICATED ON THE TMC100
LABEL.
VIARIS COMBI
HOUSEHOLD +
CHARGER
CIRCUIT
HOUSEHOLD +
I máx 100 A
CHARGER
I máx 100 A
HOUSEHOLD
L
METER
HOUSEHOLD
METER