N.B.Make sure that fans, ceiling lights, electric cables and any other electric equipment are not
wetted during cleaning.

19.Dismantling the cabinet

The unit must be disposed of in accordance with your country's waste management legislation and in
respect of our environment.
This product is considered by current legislation as hazardous waste. It must therefore be collected
separately and cannot be treated as household waste nor sent to a landfill. Before disposing of the unit,
the coolant must be collected and the lubricant oil removed. The user is responsible for delivering the
product for disposal to the collection centre specified by the local authorities or manufacturer for the
recovery and recycling of materials. This product consists of 75% recyclable materials.
Materials used in construction:
- Tubes, steel profiles and sheets: lower frame, rods and shelves
- Copper, Aluminium:
- Galvanized steel sheet:
- Foam polystyrene (R134a):
- Tempered glass:
- Wood:
- ABS:
- Polystyrene:
- Polycarbonate:
- Methacrylate:
This product contains HFC, a refrigerating gas with a high Global Warming Potential (GWP).
ARNEG equips its cabinets with refrigeration units incorporating the following types of refrigerating
gasses:
R 134a; GWP
= 1300
(100)
R 404A; GWP
= 3750
(100)
in the family of the HFCs, which are fluoridated gasses with a high global warming potential (GWP),
regulated by the Kyoto protocol (check on the rating plate or adhesive label on the compressor which
of these two gasses is used in the unit).
Therefore:
THE COMPONENTS OF THE REFRIGERATING CIRCUIT MUST NOT BE CUT OR SEPARATED,
BUT MUST BE TAKEN INTACT TO CENTRES SPECIALISED IN RECYCLING REFRIGERATING
GAS.
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic
inspections for leakage of the refrigerating gas (Presidential Decree no. 147 of February 15, 2006
Art. 3 and 4).

20.Prohibitions and prescriptions

It is recommended that the Installation and Use Manual be read carefully, so that the operator, in the
case of malfunction, is able to provide precise information to Technical Assistanceby telephone.
Before carrying out any maintenance work on the refrigerator unit, please ensure that the electrical
supply is disconnected.
In the case in which the customer notes type of anomaly in unit performance, before worrying and
contacting Customer Assistance, it is very important that the following items are checked:
- The refrigeration unit is intended to maintain the temperature of the displayed goods and not
to reduce it. Foodstuffs should only be placed inside if they are already cooled to their
respective conservation temperatures. As such, products that have been warmed up must not
be placed in the unit.
- The units are designed and built to store and display only fresh and frozen foods, ice creams,
cooked and pre-cooked items (canteens).
Do not introduce any other type of goods than those specified such as pharmaceutical
products, fishing bait etc.
- Take great care over all working manoeuvres (loading, unloading, cleaning, counter service,
maintenance, etc.). and always apply maximum diligence, using appropriate protective
equipment for the various operations.
- Do not remove protective covers or panels requiring tools for removal.
More specifically, do not remove the cover of the electrical panel. These operations must
34
refrigerating circuit, electric system and upper ceiling light
motor base, lower panels, painted panels, base structure
thermal insulation
upper shelves (glass sides)
foamed tray side frames
bumper and handrail
thermoformed side panels
lamp protection
sides