1. Beam;
2. Refractory material insulation;
3. Pothole;
4. Metal protection
WARNING:
The company declines all responsibility for the malfunctioning
of a facility that does not comply with the prescriptions of
these instructions or for the use of inappropriate additional
products.
5.3

CHIMNEY

The chimney is very important for the proper operation of the stove and it has two functions:
Evacuate the smoke and the gas safely out of the house.
Provide a draft enough to the stove or insert.
The draft also affects the intensity of the combustion and the heating performance of your equipment. A good draft of the fireplace needs a reduced
regulation of the air for the combustion, while a lack of draft needs a good regulation of the air for the combustion.
Therefore, it is essential that it is made perfectly and that it is subjected to maintenance operations in order to keep it in good conditions. (Many of the
claims due to malfunctioning reasons refer exclusively to a bad draft).
It is necessary to comply with the following requirements for the proper operation of the stove:
The interior section must be preferably circular.
It must be thermally insulated along its entire length in order to prevent condensation (the smoke is liquefied by heat shock) and even more if the
installation is outside the house.
If we use metallic pipe for the installation outside the house, it is compulsory to use thermal insulated pipe. It consist of two concentric pipes and,
between them, there is a thermal insulator. Moreover, we will avoid condensation problems.
It should not have bottlenecks (enlargements or reductions) and it must be vertical with deviations not higher that 45º.
If it has been used previously, it must be clean.
Respect the technical data of the instructions manual.
The optimum draft varies between 10 and 14 (Pascal). The measuring must be always made with the equipment hot (nominal heating power). A
lower value causes a bad combustion causing carbonic deposits and excessive smoke generation, having leaks and, even worse, an increase of the
temperature that could damage the structural components of the stove. When pressure exceeds 15 Pa it will be necessary reduce it by installing an
additional draft regulator.
To check if the combustion is correct, control if the smoke out the chimney is transparent. If the smoke is white it means that the equipment is not properly
regulated or the used pellet that is being used is too wet. However, if the smoke is grey or black it means that the combustion is not completed (it is
necessary a greater amount of secondary air).
The connection of the stove must be done with rigid aluminized steel pipes or stainless steel pipes. It is forbidden to use flexible metallic pipes or fibre
cement pipes because they damage the safety of the connection as they are subject to jerks and breaks, which causes smoke looses.
Materials that are prohibited for the chimney and, therefore, damage the proper functioning of the equipment are: fibre
cement, galvanized steel and rough and porous interior surfaces. An example of solution is described below:
(1) Stainless steel AISI 316 chimney with double insulated chamber and material resistant up to 400°C. Efficiency 100%
optimum.
All stoves that send smoke to the exterior should
have their own chimney. Never use the same
chimney for several equipments at the
same time.
Stainless steel AISI 316
chimney
As far possible, avoid horizontal sections. The
horizontal section will not be longer than 3 meters.
It must be installed a "T" with hermetic cover at the stove exit smoke that allows
the regular inspection or the heavy dust download.
There will not be more than 4 changes of direction, including the register "T" for
the cleaning.
(1)
(3) 10 mm
(3) 10 mm
(2)
(4)
(1)
(3) 10-50 mm
(3) 10 mm
(2)
(2)
Never use the same chimney for several equipments at the same time
(1)
(1)
(3) 10 mm
(2)
(2)
(1)
(1)
(3) 10 mm
(2)
EN
(4)
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Slim 9Slim 12

Table des Matières