Leister GEOSTAR G5 Instructions D'utilisation page 67

Masquer les pouces Voir aussi pour GEOSTAR G5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Welding wedge position factory setting
D. While unclamped, release the upper
contacting system locking screw (21)
and the lower contacting system lo-
cking screw (22). Screw the upper
contacting system adjusting screw
(19) and the lower contacting system
adjusting screw (20) with a socket
wrench (wrench size 4 mm) a su cient
distance away from the welding wedge
(5).
E. Insert test strips (lower & upper mem-
branes) of the material to be welded
between the upper and lower drive/
pressure rollers (16/17) and between
the upper and lower contacting sys-
tems (14/15) and welding wedge (5).
Press the clamping lever lock (10) and
close the clamping arm (4) using the
clamping lever (7) while at the same
time using the other hand to accomplish
this by holding the automatic welding
machine fi rmly by the handle (11). Ro-
tate the welding force adjustment ring
(8) until the pressure rollers touch lightly
against the material to be welded.
11
7
8
4
5
10
14
19
21
22
20
15
16
17
67

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Geostar g7

Table des Matières