The XLO
feature of some of the rangetop burners will
make the flame cycle on and off when the knob is set to the
XLO range. This is normal operation.
Repeat the Ignition and Flame Test procedures, described
for each rangetop burner.
Yellow Flames:
Further Adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas
Soft Blue Flames:
Normal for Natural Gas
If the flame is completely or mostly yellow, verify that the
regulator is set for the correct fuel. After adjustment,
retest.
Some orange-colored streaking is normal during the
initial start-up. Allow unit to operate 4-5 minutes and re-
evaluate before making adjustments.
When Flame is Properly Adjusted:
There should be a flame at each burner port. There should
be no air gap between the flame and burner port.
®
Call THERMADOR
service if:
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
Installation Instructions